# LVPS trip messages from MRS DAQ LogManager. S.Chekanov (ANL) 02 Jun 2012 07:13:53 CEST LBC60 seems to be off (at least the ROD link is off). [Run #204265 LB #135] 02 Jun 2012 07:15:20 CEST Start reconfiguring drawer TileLBC60, RunNumber 204265, LBN 136 02 Jun 2012 07:15:33 CEST Drawer TileLBC60 reconfigured, RunNumber 204265, LBN 136 02 Jun 2012 07:16:33 CEST LBC37 seems to be off (at least the ROD link is off). [Run #204265 LB #138] 02 Jun 2012 07:18:10 CEST Start reconfiguring drawer TileLBC37, RunNumber 204265, LBN 140 02 Jun 2012 07:18:22 CEST Drawer TileLBC37 reconfigured, RunNumber 204265, LBN 140 02 Jun 2012 07:18:33 CEST LBC55 seems to be off (at least the ROD link is off). [Run #204265 LB #141] 02 Jun 2012 07:18:52 CEST LBA01 seems to be off (at least the ROD link is off). [Run #204265 LB #141] 02 Jun 2012 07:19:44 CEST LBA60 seems to be off (at least the ROD link is off). [Run #204265 LB #142] 02 Jun 2012 07:20:00 CEST Start reconfiguring drawer TileLBC55, RunNumber 204265, LBN 142 02 Jun 2012 07:20:13 CEST Drawer TileLBC55 reconfigured, RunNumber 204265, LBN 142 02 Jun 2012 07:20:30 CEST Start reconfiguring drawer TileLBA01, RunNumber 204265, LBN 143 02 Jun 2012 07:20:42 CEST Drawer TileLBA01 reconfigured, RunNumber 204265, LBN 143 02 Jun 2012 07:21:31 CEST Start reconfiguring drawer TileLBA60, RunNumber 204265, LBN 144 02 Jun 2012 07:21:43 CEST Drawer TileLBA60 reconfigured, RunNumber 204265, LBN 144 02 Jun 2012 07:33:03 CEST LBA30 seems to be off (at least the ROD link is off). [Run #204265 LB #157] 02 Jun 2012 07:34:30 CEST Start reconfiguring drawer TileLBA30, RunNumber 204265, LBN 158 02 Jun 2012 07:34:42 CEST Drawer TileLBA30 reconfigured, RunNumber 204265, LBN 158 02 Jun 2012 07:34:43 CEST LBA59 seems to be off (at least the ROD link is off). [Run #204265 LB #158] 02 Jun 2012 07:36:10 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 159 02 Jun 2012 07:36:23 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 159 02 Jun 2012 07:38:00 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 07:39:03 CEST EBA21 seems to be off (at least the ROD link is off). [Run #204265 LB #162] 02 Jun 2012 07:40:23 CEST LBA33 seems to be off (at least the ROD link is off). [Run #204265 LB #164] 02 Jun 2012 07:40:41 CEST Start reconfiguring drawer TileEBA21, RunNumber 204265, LBN 164 02 Jun 2012 07:40:52 CEST Drawer TileEBA21 reconfigured, RunNumber 204265, LBN 164 02 Jun 2012 07:42:11 CEST Start reconfiguring drawer TileLBA33, RunNumber 204265, LBN 165 02 Jun 2012 07:42:23 CEST Drawer TileLBA33 reconfigured, RunNumber 204265, LBN 165 02 Jun 2012 07:55:43 CEST EBA25 seems to be off (at least the ROD link is off). [Run #204265 LB #180] 02 Jun 2012 07:57:11 CEST Start reconfiguring drawer TileEBA25, RunNumber 204265, LBN 181 02 Jun 2012 07:57:22 CEST Drawer TileEBA25 reconfigured, RunNumber 204265, LBN 181 02 Jun 2012 08:00:54 CEST LBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #185] 02 Jun 2012 08:02:21 CEST Start reconfiguring drawer TileLBA24, RunNumber 204265, LBN 186 02 Jun 2012 08:02:33 CEST Drawer TileLBA24 reconfigured, RunNumber 204265, LBN 186 02 Jun 2012 08:04:43 CEST LBA01 seems to be off (at least the ROD link is off). [Run #204265 LB #189] 02 Jun 2012 08:06:03 CEST EBC11 seems to be off (at least the ROD link is off). [Run #204265 LB #190] 02 Jun 2012 08:06:40 CEST Start reconfiguring drawer TileLBA01, RunNumber 204265, LBN 190 02 Jun 2012 08:06:52 CEST Drawer TileLBA01 reconfigured, RunNumber 204265, LBN 190 02 Jun 2012 08:07:40 CEST Start reconfiguring drawer TileEBC11, RunNumber 204265, LBN 191 02 Jun 2012 08:07:52 CEST Drawer TileEBC11 reconfigured, RunNumber 204265, LBN 191 02 Jun 2012 08:07:53 CEST LBC10 seems to be off (at least the ROD link is off). [Run #204265 LB #192] 02 Jun 2012 08:09:20 CEST Start reconfiguring drawer TileLBC10, RunNumber 204265, LBN 193 02 Jun 2012 08:09:32 CEST Drawer TileLBC10 reconfigured, RunNumber 204265, LBN 193 02 Jun 2012 08:11:33 CEST LBC64 seems to be off (at least the ROD link is off). [Run #204265 LB #195] 02 Jun 2012 08:13:10 CEST Start reconfiguring drawer TileLBC64, RunNumber 204265, LBN 197 02 Jun 2012 08:13:22 CEST Drawer TileLBC64 reconfigured, RunNumber 204265, LBN 197 02 Jun 2012 08:14:34 CEST LBC56 seems to be off (at least the ROD link is off). [Run #204265 LB #198] 02 Jun 2012 08:16:21 CEST Start reconfiguring drawer TileLBC56, RunNumber 204265, LBN 200 02 Jun 2012 08:16:33 CEST Drawer TileLBC56 reconfigured, RunNumber 204265, LBN 200 02 Jun 2012 08:18:08 CEST Low PPM trigger rate in Tile module LBC56 Tower 5. Tower ID 0x071e0603, Eta=-0.45 Phi=-0.83 (-5,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:18:08 CEST Low PPM trigger rate in Tile module LBC56 Tower 6. Tower ID 0x071e0601, Eta=-0.55 Phi=-0.83 (-6,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:18:12 CEST Low PPM trigger rate in Tile module LBC56 Tower 3. Tower ID 0x071f0703, Eta=-0.25 Phi=-0.83 (-3,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:18:12 CEST Low PPM trigger rate in Tile module LBC56 Tower 1. Tower ID 0x071f0603, Eta=-0.05 Phi=-0.83 (-1,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:19:43 CEST LBA14 seems to be off (at least the ROD link is off). [Run #204265 LB #203] 02 Jun 2012 08:21:10 CEST Start reconfiguring drawer TileLBA14, RunNumber 204265, LBN 205 02 Jun 2012 08:21:22 CEST Drawer TileLBA14 reconfigured, RunNumber 204265, LBN 205 02 Jun 2012 08:35:04 CEST LBA52 seems to be off (at least the ROD link is off). [Run #204265 LB #219] 02 Jun 2012 08:36:41 CEST Start reconfiguring drawer TileLBA52, RunNumber 204265, LBN 221 02 Jun 2012 08:36:53 CEST Drawer TileLBA52 reconfigured, RunNumber 204265, LBN 221 02 Jun 2012 08:38:11 CEST Low PPM trigger rate in Tile module LBC56 Tower 6. Tower ID 0x071e0601, Eta=-0.55 Phi=-0.83 (-6,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:38:11 CEST Low PPM trigger rate in Tile module LBC56 Tower 5. Tower ID 0x071e0603, Eta=-0.45 Phi=-0.83 (-5,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:38:14 CEST Low PPM trigger rate in Tile module LBC56 Tower 1. Tower ID 0x071f0603, Eta=-0.05 Phi=-0.83 (-1,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:38:14 CEST Low PPM trigger rate in Tile module LBC56 Tower 3. Tower ID 0x071f0703, Eta=-0.25 Phi=-0.83 (-3,55). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 08:39:44 CEST LBC30 seems to be off (at least the ROD link is off). [Run #204265 LB #224] 02 Jun 2012 08:41:03 CEST LBA07 seems to be off (at least the ROD link is off). [Run #204265 LB #226] 02 Jun 2012 08:41:03 CEST Start reconfiguring drawer TileLBC56, RunNumber 204265, LBN 225 02 Jun 2012 08:41:16 CEST Drawer TileLBC56 reconfigured, RunNumber 204265, LBN 225 02 Jun 2012 08:41:24 CEST Start reconfiguring drawer TileLBC30, RunNumber 204265, LBN 227 02 Jun 2012 08:41:37 CEST Drawer TileLBC30 reconfigured, RunNumber 204265, LBN 227 02 Jun 2012 08:42:30 CEST Start reconfiguring drawer TileLBA07, RunNumber 204265, LBN 228 02 Jun 2012 08:42:43 CEST Drawer TileLBA07 reconfigured, RunNumber 204265, LBN 228 02 Jun 2012 08:53:14 CEST LBC59 seems to be off (at least the ROD link is off). [Run #204265 LB #240] 02 Jun 2012 08:54:14 CEST LBC28 seems to be off (at least the ROD link is off). [Run #204265 LB #241] 02 Jun 2012 08:54:51 CEST Start reconfiguring drawer TileLBC59, RunNumber 204265, LBN 241 02 Jun 2012 08:55:03 CEST Drawer TileLBC59 reconfigured, RunNumber 204265, LBN 241 02 Jun 2012 08:55:50 CEST Start reconfiguring drawer TileLBC28, RunNumber 204265, LBN 242 02 Jun 2012 08:56:03 CEST Drawer TileLBC28 reconfigured, RunNumber 204265, LBN 242 02 Jun 2012 09:01:54 CEST LBA17 seems to be off (at least the ROD link is off). [Run #204265 LB #248] 02 Jun 2012 09:03:21 CEST Start reconfiguring drawer TileLBA17, RunNumber 204265, LBN 250 02 Jun 2012 09:03:33 CEST Drawer TileLBA17 reconfigured, RunNumber 204265, LBN 250 02 Jun 2012 09:04:43 CEST LBA64 seems to be off (at least the ROD link is off). [Run #204265 LB #254] 02 Jun 2012 09:06:30 CEST Start reconfiguring drawer TileLBA64, RunNumber 204265, LBN 255 02 Jun 2012 09:06:43 CEST Drawer TileLBA64 reconfigured, RunNumber 204265, LBN 255 02 Jun 2012 09:10:34 CEST LBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #261] 02 Jun 2012 09:11:44 CEST LBA35 seems to be off (at least the ROD link is off). [Run #204265 LB #262] 02 Jun 2012 09:12:11 CEST Start reconfiguring drawer TileLBA24, RunNumber 204265, LBN 263 02 Jun 2012 09:12:23 CEST Drawer TileLBA24 reconfigured, RunNumber 204265, LBN 263 02 Jun 2012 09:13:31 CEST Start reconfiguring drawer TileLBA35, RunNumber 204265, LBN 264 02 Jun 2012 09:13:44 CEST Drawer TileLBA35 reconfigured, RunNumber 204265, LBN 264 02 Jun 2012 09:27:14 CEST LBA34 seems to be off (at least the ROD link is off). [Run #204265 LB #278] 02 Jun 2012 09:28:04 CEST LBC54 seems to be off (at least the ROD link is off). [Run #204265 LB #279] 02 Jun 2012 09:28:41 CEST Start reconfiguring drawer TileLBA34, RunNumber 204265, LBN 280 02 Jun 2012 09:28:53 CEST Drawer TileLBA34 reconfigured, RunNumber 204265, LBN 280 02 Jun 2012 09:29:31 CEST Start reconfiguring drawer TileLBC54, RunNumber 204265, LBN 280 02 Jun 2012 09:29:44 CEST Drawer TileLBC54 reconfigured, RunNumber 204265, LBN 280 02 Jun 2012 09:38:54 CEST LBC55 seems to be off (at least the ROD link is off). [Run #204265 LB #290] 02 Jun 2012 09:40:21 CEST Start reconfiguring drawer TileLBC55, RunNumber 204265, LBN 291 02 Jun 2012 09:40:24 CEST LBA43 seems to be off (at least the ROD link is off). [Run #204265 LB #291] 02 Jun 2012 09:40:34 CEST Drawer TileLBC55 reconfigured, RunNumber 204265, LBN 291 02 Jun 2012 09:41:34 CEST LBC28 seems to be off (at least the ROD link is off). [Run #204265 LB #292] 02 Jun 2012 09:42:14 CEST EBC50 seems to be off (at least the ROD link is off). [Run #204265 LB #293] 02 Jun 2012 09:42:22 CEST Start reconfiguring drawer TileLBA43, RunNumber 204265, LBN 293 02 Jun 2012 09:42:34 CEST Drawer TileLBA43 reconfigured, RunNumber 204265, LBN 293 02 Jun 2012 09:43:01 CEST Start reconfiguring drawer TileLBC28, RunNumber 204265, LBN 294 02 Jun 2012 09:43:13 CEST Drawer TileLBC28 reconfigured, RunNumber 204265, LBN 294 02 Jun 2012 09:43:41 CEST Start reconfiguring drawer TileEBC50, RunNumber 204265, LBN 294 02 Jun 2012 09:43:53 CEST Drawer TileEBC50 reconfigured, RunNumber 204265, LBN 294 02 Jun 2012 09:50:54 CEST LBC02 seems to be off (at least the ROD link is off). [Run #204265 LB #302] 02 Jun 2012 09:52:21 CEST Start reconfiguring drawer TileLBC02, RunNumber 204265, LBN 303 02 Jun 2012 09:52:33 CEST Drawer TileLBC02 reconfigured, RunNumber 204265, LBN 303 02 Jun 2012 10:00:15 CEST EBA45 seems to be off (at least the ROD link is off). [Run #204265 LB #311] 02 Jun 2012 10:01:52 CEST Start reconfiguring drawer TileEBA45, RunNumber 204265, LBN 312 02 Jun 2012 10:02:03 CEST Drawer TileEBA45 reconfigured, RunNumber 204265, LBN 312 02 Jun 2012 10:09:14 CEST LBA07 seems to be off (at least the ROD link is off). [Run #204265 LB #320] 02 Jun 2012 10:11:01 CEST Start reconfiguring drawer TileLBA07, RunNumber 204265, LBN 322 02 Jun 2012 10:11:13 CEST Drawer TileLBA07 reconfigured, RunNumber 204265, LBN 322 02 Jun 2012 10:11:25 CEST LBC53 seems to be off (at least the ROD link is off). [Run #204265 LB #322] 02 Jun 2012 10:11:54 CEST EBA01 seems to be off (at least the ROD link is off). [Run #204265 LB #322] 02 Jun 2012 10:13:12 CEST Start reconfiguring drawer TileLBC53, RunNumber 204265, LBN 324 02 Jun 2012 10:13:24 CEST Drawer TileLBC53 reconfigured, RunNumber 204265, LBN 324 02 Jun 2012 10:13:31 CEST Start reconfiguring drawer TileEBA01, RunNumber 204265, LBN 324 02 Jun 2012 10:13:43 CEST Drawer TileEBA01 reconfigured, RunNumber 204265, LBN 324 02 Jun 2012 10:17:55 CEST LBA29 seems to be off (at least the ROD link is off). [Run #204265 LB #328] 02 Jun 2012 10:19:52 CEST Start reconfiguring drawer TileLBA29, RunNumber 204265, LBN 330 02 Jun 2012 10:20:04 CEST Drawer TileLBA29 reconfigured, RunNumber 204265, LBN 330 02 Jun 2012 10:48:45 CEST LBA50 seems to be off (at least the ROD link is off). [Run #204265 LB #360] 02 Jun 2012 10:50:12 CEST Start reconfiguring drawer TileLBA50, RunNumber 204265, LBN 361 02 Jun 2012 10:50:24 CEST Drawer TileLBA50 reconfigured, RunNumber 204265, LBN 361 02 Jun 2012 10:51:04 CEST EBC10 seems to be off (at least the ROD link is off). [Run #204265 LB #362] 02 Jun 2012 10:52:51 CEST Start reconfiguring drawer TileEBC10, RunNumber 204265, LBN 364 02 Jun 2012 10:53:03 CEST Drawer TileEBC10 reconfigured, RunNumber 204265, LBN 364 02 Jun 2012 10:57:11 CEST Start reconfiguring drawer TileLBA17, RunNumber 204265, LBN 368 02 Jun 2012 10:57:23 CEST Drawer TileLBA17 reconfigured, RunNumber 204265, LBN 368 02 Jun 2012 10:58:15 CEST LBC32 seems to be off (at least the ROD link is off). [Run #204265 LB #369] 02 Jun 2012 10:58:35 CEST LBA44 seems to be off (at least the ROD link is off). [Run #204265 LB #369] 02 Jun 2012 10:59:42 CEST Start reconfiguring drawer TileLBC32, RunNumber 204265, LBN 370 02 Jun 2012 10:59:54 CEST Drawer TileLBC32 reconfigured, RunNumber 204265, LBN 370 02 Jun 2012 11:00:12 CEST Start reconfiguring drawer TileLBA44, RunNumber 204265, LBN 371 02 Jun 2012 11:00:24 CEST Drawer TileLBA44 reconfigured, RunNumber 204265, LBN 371 02 Jun 2012 11:02:44 CEST LBC01 seems to be off (at least the ROD link is off). [Run #204265 LB #374] 02 Jun 2012 11:03:55 CEST LBA54 seems to be off (at least the ROD link is off). [Run #204265 LB #375] 02 Jun 2012 11:04:21 CEST Start reconfiguring drawer TileLBC01, RunNumber 204265, LBN 375 02 Jun 2012 11:04:34 CEST Drawer TileLBC01 reconfigured, RunNumber 204265, LBN 375 02 Jun 2012 11:05:23 CEST Start reconfiguring drawer TileLBA54, RunNumber 204265, LBN 376 02 Jun 2012 11:05:35 CEST Drawer TileLBA54 reconfigured, RunNumber 204265, LBN 376 02 Jun 2012 11:18:25 CEST LBC21 seems to be off (at least the ROD link is off). [Run #204265 LB #389] 02 Jun 2012 11:18:35 CEST LBA34 seems to be off (at least the ROD link is off). [Run #204265 LB #389] 02 Jun 2012 11:20:02 CEST Start reconfiguring drawer TileLBC21, RunNumber 204265, LBN 390 02 Jun 2012 11:20:14 CEST Drawer TileLBC21 reconfigured, RunNumber 204265, LBN 390 02 Jun 2012 11:20:22 CEST Start reconfiguring drawer TileLBA34, RunNumber 204265, LBN 391 02 Jun 2012 11:20:35 CEST Drawer TileLBA34 reconfigured, RunNumber 204265, LBN 391 02 Jun 2012 11:26:26 CEST LBA58 seems to be off (at least the ROD link is off). [Run #204265 LB #397] 02 Jun 2012 11:28:23 CEST Start reconfiguring drawer TileLBA58, RunNumber 204265, LBN 399 02 Jun 2012 11:28:35 CEST Drawer TileLBA58 reconfigured, RunNumber 204265, LBN 399 02 Jun 2012 11:30:25 CEST EBC21 seems to be off (at least the ROD link is off). [Run #204265 LB #401] 02 Jun 2012 11:31:52 CEST Start reconfiguring drawer TileEBC21, RunNumber 204265, LBN 402 02 Jun 2012 11:32:03 CEST Drawer TileEBC21 reconfigured, RunNumber 204265, LBN 402 02 Jun 2012 11:45:25 CEST LBA35 seems to be off (at least the ROD link is off). [Run #204265 LB #417] 02 Jun 2012 11:47:42 CEST Start reconfiguring drawer TileLBA35, RunNumber 204265, LBN 419 02 Jun 2012 11:47:55 CEST Drawer TileLBA35 reconfigured, RunNumber 204265, LBN 419 02 Jun 2012 11:51:15 CEST LBA10 seems to be off (at least the ROD link is off). [Run #204265 LB #422] 02 Jun 2012 11:52:42 CEST Start reconfiguring drawer TileLBA10, RunNumber 204265, LBN 424 02 Jun 2012 11:52:55 CEST Drawer TileLBA10 reconfigured, RunNumber 204265, LBN 424 02 Jun 2012 11:54:26 CEST Low PPM trigger rate in Tile module LBA10 Tower 7. Tower ID 0x06110901, Eta=0.65 Phi=0.93 (6,9). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 11:54:29 CEST Low PPM trigger rate in Tile module LBA10 Tower 8. Tower ID 0x06110903, Eta=0.75 Phi=0.93 (7,9). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 11:54:29 CEST Low PPM trigger rate in Tile module LBA10 Tower 5. Tower ID 0x06110801, Eta=0.45 Phi=0.93 (4,9). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 11:57:06 CEST LBC50 seems to be off (at least the ROD link is off). [Run #204265 LB #428] 02 Jun 2012 11:58:05 CEST EBC62 seems to be off (at least the ROD link is off). [Run #204265 LB #429] 02 Jun 2012 11:58:33 CEST Start reconfiguring drawer TileLBC50, RunNumber 204265, LBN 429 02 Jun 2012 11:58:45 CEST Drawer TileLBC50 reconfigured, RunNumber 204265, LBN 429 02 Jun 2012 11:59:42 CEST Start reconfiguring drawer TileEBC62, RunNumber 204265, LBN 430 02 Jun 2012 11:59:53 CEST Drawer TileEBC62 reconfigured, RunNumber 204265, LBN 430 02 Jun 2012 12:00:05 CEST LBC22 seems to be off (at least the ROD link is off). [Run #204265 LB #431] 02 Jun 2012 12:01:12 CEST Start reconfiguring drawer TileLBA10, RunNumber 204265, LBN 432 02 Jun 2012 12:01:24 CEST Drawer TileLBA10 reconfigured, RunNumber 204265, LBN 432 02 Jun 2012 12:01:42 CEST Start reconfiguring drawer TileLBC22, RunNumber 204265, LBN 432 02 Jun 2012 12:01:55 CEST Drawer TileLBC22 reconfigured, RunNumber 204265, LBN 432 02 Jun 2012 12:13:26 CEST LBA32 seems to be off (at least the ROD link is off). [Run #204265 LB #444] 02 Jun 2012 12:15:23 CEST Start reconfiguring drawer TileLBA32, RunNumber 204265, LBN 446 02 Jun 2012 12:15:35 CEST Drawer TileLBA32 reconfigured, RunNumber 204265, LBN 446 02 Jun 2012 12:23:46 CEST LBC54 seems to be off (at least the ROD link is off). [Run #204265 LB #454] 02 Jun 2012 12:23:55 CEST LBA01 seems to be off (at least the ROD link is off). [Run #204265 LB #454] 02 Jun 2012 12:25:22 CEST Start reconfiguring drawer TileLBA01, RunNumber 204265, LBN 456 02 Jun 2012 12:25:24 CEST Start reconfiguring drawer TileLBC54, RunNumber 204265, LBN 456 02 Jun 2012 12:25:35 CEST Drawer TileLBA01 reconfigured, RunNumber 204265, LBN 456 02 Jun 2012 12:25:36 CEST Drawer TileLBC54 reconfigured, RunNumber 204265, LBN 456 02 Jun 2012 12:38:15 CEST EBC01 seems to be off (at least the ROD link is off). [Run #204265 LB #471] 02 Jun 2012 12:39:32 CEST Start reconfiguring drawer TileEBC01, RunNumber 204265, LBN 472 02 Jun 2012 12:39:44 CEST Drawer TileEBC01 reconfigured, RunNumber 204265, LBN 472 02 Jun 2012 12:42:16 CEST LBA28 seems to be off (at least the ROD link is off). [Run #204265 LB #475] 02 Jun 2012 12:42:26 CEST LBA20 seems to be off (at least the ROD link is off). [Run #204265 LB #475] 02 Jun 2012 12:43:43 CEST Start reconfiguring drawer TileLBA28, RunNumber 204265, LBN 476 02 Jun 2012 12:43:55 CEST Drawer TileLBA28 reconfigured, RunNumber 204265, LBN 476 02 Jun 2012 12:43:56 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 12:44:04 CEST Start reconfiguring drawer TileLBA20, RunNumber 204265, LBN 476 02 Jun 2012 12:44:16 CEST Drawer TileLBA20 reconfigured, RunNumber 204265, LBN 476 02 Jun 2012 12:47:03 CEST Start reconfiguring drawer TileEBC01, RunNumber 204265, LBN 479 02 Jun 2012 12:47:15 CEST Drawer TileEBC01 reconfigured, RunNumber 204265, LBN 479 02 Jun 2012 12:50:36 CEST LBC19 seems to be off (at least the ROD link is off). [Run #204265 LB #483] 02 Jun 2012 12:52:03 CEST Start reconfiguring drawer TileLBC19, RunNumber 204265, LBN 484 02 Jun 2012 12:52:15 CEST Drawer TileLBC19 reconfigured, RunNumber 204265, LBN 484 02 Jun 2012 12:58:56 CEST EBA60 seems to be off (at least the ROD link is off). [Run #204265 LB #501] 02 Jun 2012 13:00:34 CEST Start reconfiguring drawer TileEBA60, RunNumber 204265, LBN 504 02 Jun 2012 13:00:45 CEST Drawer TileEBA60 reconfigured, RunNumber 204265, LBN 504 02 Jun 2012 13:04:31 CEST Start reconfiguring drawer TileEBA60, RunNumber 204265, LBN 512 02 Jun 2012 13:04:43 CEST Drawer TileEBA60 reconfigured, RunNumber 204265, LBN 512 02 Jun 2012 13:20:36 CEST EBC47 seems to be off (at least the ROD link is off). [Run #204265 LB #554] 02 Jun 2012 13:22:13 CEST Start reconfiguring drawer TileEBC47, RunNumber 204265, LBN 557 02 Jun 2012 13:22:25 CEST Drawer TileEBC47 reconfigured, RunNumber 204265, LBN 557 02 Jun 2012 13:27:56 CEST LBC30 seems to be off (at least the ROD link is off). [Run #204265 LB #570] 02 Jun 2012 13:29:22 CEST Start reconfiguring drawer TileEBC62, RunNumber 204265, LBN 573 02 Jun 2012 13:29:24 CEST Start reconfiguring drawer TileLBC30, RunNumber 204265, LBN 573 02 Jun 2012 13:29:33 CEST Drawer TileEBC62 reconfigured, RunNumber 204265, LBN 573 02 Jun 2012 13:29:36 CEST Drawer TileLBC30 reconfigured, RunNumber 204265, LBN 573 02 Jun 2012 13:39:36 CEST LBA16 seems to be off (at least the ROD link is off). [Run #204265 LB #587] 02 Jun 2012 13:41:14 CEST Start reconfiguring drawer TileLBA16, RunNumber 204265, LBN 589 02 Jun 2012 13:41:26 CEST Drawer TileLBA16 reconfigured, RunNumber 204265, LBN 589 02 Jun 2012 13:42:16 CEST LBC12 seems to be off (at least the ROD link is off). [Run #204265 LB #590] 02 Jun 2012 13:43:43 CEST Start reconfiguring drawer TileLBC12, RunNumber 204265, LBN 591 02 Jun 2012 13:43:55 CEST Drawer TileLBC12 reconfigured, RunNumber 204265, LBN 591 02 Jun 2012 13:55:07 CEST LBA54 seems to be off (at least the ROD link is off). [Run #204265 LB #603] 02 Jun 2012 13:56:54 CEST Start reconfiguring drawer TileLBA54, RunNumber 204265, LBN 605 02 Jun 2012 13:57:06 CEST Drawer TileLBA54 reconfigured, RunNumber 204265, LBN 605 02 Jun 2012 14:03:06 CEST LBA17 seems to be off (at least the ROD link is off). [Run #204265 LB #613] 02 Jun 2012 14:04:17 CEST LBA59 seems to be off (at least the ROD link is off). [Run #204265 LB #614] 02 Jun 2012 14:04:53 CEST Start reconfiguring drawer TileLBA17, RunNumber 204265, LBN 616 02 Jun 2012 14:05:06 CEST Drawer TileLBA17 reconfigured, RunNumber 204265, LBN 616 02 Jun 2012 14:05:07 CEST LBA54 seems to be off (at least the ROD link is off). [Run #204265 LB #616] 02 Jun 2012 14:05:54 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 617 02 Jun 2012 14:06:06 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 617 02 Jun 2012 14:07:04 CEST Start reconfiguring drawer TileLBA54, RunNumber 204265, LBN 618 02 Jun 2012 14:07:16 CEST Drawer TileLBA54 reconfigured, RunNumber 204265, LBN 618 02 Jun 2012 14:08:17 CEST LBC12 seems to be off (at least the ROD link is off). [Run #204265 LB #619] 02 Jun 2012 14:10:04 CEST Start reconfiguring drawer TileLBC12, RunNumber 204265, LBN 621 02 Jun 2012 14:10:16 CEST Drawer TileLBC12 reconfigured, RunNumber 204265, LBN 621 02 Jun 2012 14:13:46 CEST LBC01 seems to be off (at least the ROD link is off). [Run #204265 LB #624] 02 Jun 2012 14:14:07 CEST EBA35 seems to be off (at least the ROD link is off). [Run #204265 LB #625] 02 Jun 2012 14:15:13 CEST Start reconfiguring drawer TileLBC01, RunNumber 204265, LBN 626 02 Jun 2012 14:15:26 CEST Drawer TileLBC01 reconfigured, RunNumber 204265, LBN 626 02 Jun 2012 14:15:34 CEST Start reconfiguring drawer TileEBA35, RunNumber 204265, LBN 626 02 Jun 2012 14:15:45 CEST Drawer TileEBA35 reconfigured, RunNumber 204265, LBN 626 02 Jun 2012 14:16:17 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 14:16:57 CEST LBA22 seems to be off (at least the ROD link is off). [Run #204265 LB #628] 02 Jun 2012 14:18:44 CEST Start reconfiguring drawer TileLBA22, RunNumber 204265, LBN 629 02 Jun 2012 14:18:56 CEST Drawer TileLBA22 reconfigured, RunNumber 204265, LBN 629 02 Jun 2012 14:19:24 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 630 02 Jun 2012 14:19:36 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 630 02 Jun 2012 14:20:37 CEST LBC17 seems to be off (at least the ROD link is off). [Run #204265 LB #631] 02 Jun 2012 14:22:04 CEST Start reconfiguring drawer TileLBC17, RunNumber 204265, LBN 632 02 Jun 2012 14:22:16 CEST Drawer TileLBC17 reconfigured, RunNumber 204265, LBN 632 02 Jun 2012 14:34:07 CEST LBC17 seems to be off (at least the ROD link is off). [Run #204265 LB #644] 02 Jun 2012 14:34:37 CEST LBA12 seems to be off (at least the ROD link is off). [Run #204265 LB #645] 02 Jun 2012 14:35:34 CEST Start reconfiguring drawer TileLBC17, RunNumber 204265, LBN 646 02 Jun 2012 14:35:46 CEST Drawer TileLBC17 reconfigured, RunNumber 204265, LBN 646 02 Jun 2012 14:36:20 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 14:36:24 CEST Start reconfiguring drawer TileLBA12, RunNumber 204265, LBN 647 02 Jun 2012 14:36:36 CEST Drawer TileLBA12 reconfigured, RunNumber 204265, LBN 647 02 Jun 2012 14:39:57 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 650 02 Jun 2012 14:40:09 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 650 02 Jun 2012 14:43:27 CEST EBC52 seems to be off (at least the ROD link is off). [Run #204265 LB #654] 02 Jun 2012 14:44:54 CEST Start reconfiguring drawer TileEBC52, RunNumber 204265, LBN 655 02 Jun 2012 14:45:05 CEST Drawer TileEBC52 reconfigured, RunNumber 204265, LBN 655 02 Jun 2012 14:46:57 CEST LBA13 seems to be off (at least the ROD link is off). [Run #204265 LB #657] 02 Jun 2012 14:48:24 CEST Start reconfiguring drawer TileLBA13, RunNumber 204265, LBN 659 02 Jun 2012 14:48:36 CEST Drawer TileLBA13 reconfigured, RunNumber 204265, LBN 659 02 Jun 2012 14:56:24 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 15:03:57 CEST LBA14 seems to be off (at least the ROD link is off). [Run #204265 LB #674] 02 Jun 2012 15:05:34 CEST Start reconfiguring drawer TileLBA14, RunNumber 204265, LBN 676 02 Jun 2012 15:05:46 CEST Drawer TileLBA14 reconfigured, RunNumber 204265, LBN 676 02 Jun 2012 15:16:28 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 15:17:18 CEST LBA59 seems to be off (at least the ROD link is off). [Run #204265 LB #687] 02 Jun 2012 15:18:55 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 689 02 Jun 2012 15:19:07 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 689 02 Jun 2012 15:30:28 CEST LBA60 seems to be off (at least the ROD link is off). [Run #204265 LB #700] 02 Jun 2012 15:31:55 CEST Start reconfiguring drawer TileLBA60, RunNumber 204265, LBN 702 02 Jun 2012 15:32:07 CEST Drawer TileLBA60 reconfigured, RunNumber 204265, LBN 702 02 Jun 2012 15:35:48 CEST EBA58 seems to be off (at least the ROD link is off). [Run #204265 LB #707] 02 Jun 2012 15:36:29 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 15:37:26 CEST Start reconfiguring drawer TileEBA58, RunNumber 204265, LBN 709 02 Jun 2012 15:37:37 CEST Drawer TileEBA58 reconfigured, RunNumber 204265, LBN 709 02 Jun 2012 15:37:58 CEST LBC38 seems to be off (at least the ROD link is off). [Run #204265 LB #710] 02 Jun 2012 15:38:27 CEST LBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #710] 02 Jun 2012 15:39:45 CEST Start reconfiguring drawer TileLBC38, RunNumber 204265, LBN 711 02 Jun 2012 15:39:54 CEST Start reconfiguring drawer TileLBA24, RunNumber 204265, LBN 711 02 Jun 2012 15:39:58 CEST Drawer TileLBC38 reconfigured, RunNumber 204265, LBN 711 02 Jun 2012 15:40:07 CEST Drawer TileLBA24 reconfigured, RunNumber 204265, LBN 711 02 Jun 2012 15:53:37 CEST LBC08 seems to be off (at least the ROD link is off). [Run #204265 LB #726] 02 Jun 2012 15:55:04 CEST Start reconfiguring drawer TileLBC08, RunNumber 204265, LBN 727 02 Jun 2012 15:55:17 CEST Drawer TileLBC08 reconfigured, RunNumber 204265, LBN 727 02 Jun 2012 15:56:30 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 15:57:28 CEST EBA47 seems to be off (at least the ROD link is off). [Run #204265 LB #730] 02 Jun 2012 15:59:05 CEST Start reconfiguring drawer TileEBA47, RunNumber 204265, LBN 731 02 Jun 2012 15:59:17 CEST Drawer TileEBA47 reconfigured, RunNumber 204265, LBN 731 02 Jun 2012 16:16:34 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:18:48 CEST LBA10 seems to be off (at least the ROD link is off). [Run #204265 LB #753] 02 Jun 2012 16:20:15 CEST Start reconfiguring drawer TileLBA10, RunNumber 204265, LBN 755 02 Jun 2012 16:20:27 CEST Drawer TileLBA10 reconfigured, RunNumber 204265, LBN 755 02 Jun 2012 16:20:27 CEST EBC14 seems to be off (at least the ROD link is off). [Run #204265 LB #755] 02 Jun 2012 16:22:05 CEST Start reconfiguring drawer TileEBC14, RunNumber 204265, LBN 756 02 Jun 2012 16:22:16 CEST Drawer TileEBC14 reconfigured, RunNumber 204265, LBN 756 02 Jun 2012 16:23:56 CEST Low PPM trigger rate in Tile module EBC14 Tower 6. Tower ID 0x07100c03, Eta=-1.45 Phi=1.33 (-15,13). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:32:48 CEST LBC14 seems to be off (at least the ROD link is off). [Run #204265 LB #767] 02 Jun 2012 16:34:15 CEST Start reconfiguring drawer TileLBC14, RunNumber 204265, LBN 768 02 Jun 2012 16:34:27 CEST Drawer TileLBC14 reconfigured, RunNumber 204265, LBN 768 02 Jun 2012 16:36:35 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:38:18 CEST LBA20 seems to be off (at least the ROD link is off). [Run #204265 LB #773] 02 Jun 2012 16:39:47 CEST Start reconfiguring drawer TileLBA20, RunNumber 204265, LBN 774 02 Jun 2012 16:40:03 CEST Drawer TileLBA20 reconfigured, RunNumber 204265, LBN 774 02 Jun 2012 16:41:39 CEST Low PPM trigger rate in Tile module LBA20 Tower 7. Tower ID 0x06150201, Eta=0.65 Phi=1.91 (6,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:41:42 CEST Low PPM trigger rate in Tile module LBA20 Tower 1. Tower ID 0x06140301, Eta=0.05 Phi=1.91 (0,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:41:42 CEST Low PPM trigger rate in Tile module LBA20 Tower 3. Tower ID 0x06140201, Eta=0.25 Phi=1.91 (2,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:41:42 CEST Low PPM trigger rate in Tile module LBA20 Tower 8. Tower ID 0x06150203, Eta=0.75 Phi=1.91 (7,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:41:42 CEST Low PPM trigger rate in Tile module LBA20 Tower 9. Tower ID 0x06160301, Eta=0.85 Phi=1.91 (8,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:41:46 CEST Low PPM trigger rate in Tile module LBA20 Tower 2. Tower ID 0x06140303, Eta=0.15 Phi=1.91 (1,19). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:43:57 CEST Low PPM trigger rate in Tile module EBC14 Tower 6. Tower ID 0x07100c03, Eta=-1.45 Phi=1.33 (-15,13). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:44:08 CEST Start reconfiguring drawer TileLBA20, RunNumber 204265, LBN 780 02 Jun 2012 16:44:20 CEST Drawer TileLBA20 reconfigured, RunNumber 204265, LBN 780 02 Jun 2012 16:44:53 CEST Start reconfiguring drawer TileEBC14, RunNumber 204265, LBN 781 02 Jun 2012 16:45:04 CEST Drawer TileEBC14 reconfigured, RunNumber 204265, LBN 781 02 Jun 2012 16:56:36 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 16:59:28 CEST EBC23 seems to be off (at least the ROD link is off). [Run #204265 LB #795] 02 Jun 2012 17:01:05 CEST Start reconfiguring drawer TileEBC23, RunNumber 204265, LBN 797 02 Jun 2012 17:01:16 CEST Drawer TileEBC23 reconfigured, RunNumber 204265, LBN 797 02 Jun 2012 17:08:08 CEST LBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #805] 02 Jun 2012 17:08:48 CEST LBC38 seems to be off (at least the ROD link is off). [Run #204265 LB #805] 02 Jun 2012 17:09:35 CEST Start reconfiguring drawer TileLBA24, RunNumber 204265, LBN 806 02 Jun 2012 17:09:48 CEST Drawer TileLBA24 reconfigured, RunNumber 204265, LBN 806 02 Jun 2012 17:10:26 CEST Start reconfiguring drawer TileLBC38, RunNumber 204265, LBN 807 02 Jun 2012 17:10:38 CEST Drawer TileLBC38 reconfigured, RunNumber 204265, LBN 807 02 Jun 2012 17:16:37 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 17:21:08 CEST LBA09 seems to be off (at least the ROD link is off). [Run #204265 LB #818] 02 Jun 2012 17:22:45 CEST Start reconfiguring drawer TileLBA09, RunNumber 204265, LBN 819 02 Jun 2012 17:22:57 CEST Drawer TileLBA09 reconfigured, RunNumber 204265, LBN 819 02 Jun 2012 17:24:28 CEST LBA12 seems to be off (at least the ROD link is off). [Run #204265 LB #821] 02 Jun 2012 17:25:55 CEST Start reconfiguring drawer TileLBA12, RunNumber 204265, LBN 822 02 Jun 2012 17:26:08 CEST Drawer TileLBA12 reconfigured, RunNumber 204265, LBN 822 02 Jun 2012 17:36:39 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 17:50:09 CEST LBA14 seems to be off (at least the ROD link is off). [Run #204265 LB #846] 02 Jun 2012 17:51:36 CEST Start reconfiguring drawer TileLBA14, RunNumber 204265, LBN 847 02 Jun 2012 17:51:48 CEST Drawer TileLBA14 reconfigured, RunNumber 204265, LBN 847 02 Jun 2012 17:56:43 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 17:59:09 CEST EBA30 seems to be off (at least the ROD link is off). [Run #204265 LB #855] 02 Jun 2012 18:00:37 CEST Start reconfiguring drawer TileEBA30, RunNumber 204265, LBN 856 02 Jun 2012 18:00:48 CEST Drawer TileEBA30 reconfigured, RunNumber 204265, LBN 856 02 Jun 2012 18:02:31 CEST Low PPM trigger rate in Tile module EBA30 Tower 5. Tower ID 0x06170c03, Eta=1.35 Phi=2.9 (13,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:02:31 CEST Low PPM trigger rate in Tile module EBA30 Tower 6. Tower ID 0x06170d01, Eta=1.45 Phi=2.9 (14,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:02:34 CEST Low PPM trigger rate in Tile module EBA30 Tower 3. Tower ID 0x06160d03, Eta=1.15 Phi=2.9 (11,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:02:34 CEST Low PPM trigger rate in Tile module EBA30 Tower 2. Tower ID 0x06160d01, Eta=1.05 Phi=2.9 (10,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:02:34 CEST Low PPM trigger rate in Tile module EBA30 Tower 4. Tower ID 0x06170c01, Eta=1.25 Phi=2.9 (12,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:05:13 CEST Low PPM trigger rate in Tile module EBA30 Tower 1. Tower ID 0x06160c03, Eta=0.95 Phi=2.9 (9,29). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:07:09 CEST Start reconfiguring drawer TileEBA30, RunNumber 204265, LBN 863 02 Jun 2012 18:07:21 CEST Drawer TileEBA30 reconfigured, RunNumber 204265, LBN 863 02 Jun 2012 18:16:44 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:25:29 CEST LBA20 seems to be off (at least the ROD link is off). [Run #204265 LB #881] 02 Jun 2012 18:26:56 CEST Start reconfiguring drawer TileLBA20, RunNumber 204265, LBN 882 02 Jun 2012 18:27:08 CEST Drawer TileLBA20 reconfigured, RunNumber 204265, LBN 882 02 Jun 2012 18:31:39 CEST EBA64 seems to be off (at least the ROD link is off). [Run #204265 LB #887] 02 Jun 2012 18:33:16 CEST Start reconfiguring drawer TileEBA64, RunNumber 204265, LBN 888 02 Jun 2012 18:33:27 CEST Drawer TileEBA64 reconfigured, RunNumber 204265, LBN 888 02 Jun 2012 18:36:46 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:38:27 CEST Low PPM trigger rate in Tile module EBA36 Tower 1. Tower ID 0x061a0303, Eta=0.95 Phi=-2.8 (9,35). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 18:40:59 CEST LBA30 seems to be off (at least the ROD link is off). [Run #204265 LB #896] 02 Jun 2012 18:42:46 CEST Start reconfiguring drawer TileLBA30, RunNumber 204265, LBN 898 02 Jun 2012 18:42:59 CEST Drawer TileLBA30 reconfigured, RunNumber 204265, LBN 898 02 Jun 2012 18:48:10 CEST LBA45 seems to be off (at least the ROD link is off). [Run #204265 LB #904] 02 Jun 2012 18:49:47 CEST Start reconfiguring drawer TileLBA45, RunNumber 204265, LBN 905 02 Jun 2012 18:49:59 CEST Drawer TileLBA45 reconfigured, RunNumber 204265, LBN 905 02 Jun 2012 18:56:47 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:03:49 CEST LBC16 seems to be off (at least the ROD link is off). [Run #204265 LB #919] 02 Jun 2012 19:06:01 CEST LBA54 seems to be off (at least the ROD link is off). [Run #204265 LB #921] 02 Jun 2012 19:07:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:12 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:12 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:25 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:07:48 CEST Start reconfiguring drawer TileLBA54, RunNumber 204265, LBN 923 02 Jun 2012 19:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:08:00 CEST Drawer TileLBA54 reconfigured, RunNumber 204265, LBN 923 02 Jun 2012 19:08:40 CEST LBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #924] 02 Jun 2012 19:10:07 CEST Start reconfiguring drawer TileLBC16, RunNumber 204265, LBN 925 02 Jun 2012 19:10:09 CEST LBC16 seems to be off (at least the ROD link is off). [Run #204265 LB #925] 02 Jun 2012 19:10:10 CEST LBC37 seems to be off (at least the ROD link is off). [Run #204265 LB #925] 02 Jun 2012 19:10:19 CEST Drawer TileLBC16 reconfigured, RunNumber 204265, LBN 925 02 Jun 2012 19:10:27 CEST Start reconfiguring drawer TileLBA24, RunNumber 204265, LBN 926 02 Jun 2012 19:10:39 CEST Drawer TileLBA24 reconfigured, RunNumber 204265, LBN 926 02 Jun 2012 19:11:47 CEST Start reconfiguring drawer TileLBC37, RunNumber 204265, LBN 927 02 Jun 2012 19:11:59 CEST Drawer TileLBC37 reconfigured, RunNumber 204265, LBN 927 02 Jun 2012 19:16:49 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:10 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:10 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:10 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:10 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:27 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:28:48 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:29:28 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:30:19 CEST LBA06 seems to be off (at least the ROD link is off). [Run #204265 LB #945] 02 Jun 2012 19:32:08 CEST Start reconfiguring drawer TileLBA06, RunNumber 204265, LBN 947 02 Jun 2012 19:32:24 CEST Drawer TileLBA06 reconfigured, RunNumber 204265, LBN 947 02 Jun 2012 19:33:41 CEST Low PPM trigger rate in Tile module LBA06 Tower 1. Tower ID 0x06100401, Eta=0.05 Phi=0.54 (0,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:33:41 CEST Low PPM trigger rate in Tile module LBA06 Tower 7. Tower ID 0x06110501, Eta=0.65 Phi=0.54 (6,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:33:41 CEST Low PPM trigger rate in Tile module LBA06 Tower 9. Tower ID 0x06120401, Eta=0.85 Phi=0.54 (8,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:33:44 CEST Low PPM trigger rate in Tile module LBA06 Tower 2. Tower ID 0x06100403, Eta=0.15 Phi=0.54 (1,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:33:44 CEST Low PPM trigger rate in Tile module LBA06 Tower 3. Tower ID 0x06100501, Eta=0.25 Phi=0.54 (2,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:36:10 CEST LBA17 seems to be off (at least the ROD link is off). [Run #204265 LB #951] 02 Jun 2012 19:36:50 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:37:00 CEST EBA23 seems to be off (at least the ROD link is off). [Run #204265 LB #952] 02 Jun 2012 19:37:37 CEST Start reconfiguring drawer TileLBA17, RunNumber 204265, LBN 952 02 Jun 2012 19:37:49 CEST Drawer TileLBA17 reconfigured, RunNumber 204265, LBN 952 02 Jun 2012 19:38:37 CEST Start reconfiguring drawer TileEBA23, RunNumber 204265, LBN 953 02 Jun 2012 19:38:49 CEST Drawer TileEBA23 reconfigured, RunNumber 204265, LBN 953 02 Jun 2012 19:42:41 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:43:40 CEST LBC16 seems to be off (at least the ROD link is off). [Run #204265 LB #959] 02 Jun 2012 19:46:50 CEST LBA28 seems to be off (at least the ROD link is off). [Run #204265 LB #962] 02 Jun 2012 19:47:11 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:11 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:11 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:47:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:48:17 CEST Start reconfiguring drawer TileLBA28, RunNumber 204265, LBN 964 02 Jun 2012 19:48:29 CEST Drawer TileLBA28 reconfigured, RunNumber 204265, LBN 964 02 Jun 2012 19:48:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:50:10 CEST LBC28 seems to be off (at least the ROD link is off). [Run #204265 LB #966] 02 Jun 2012 19:51:27 CEST Start reconfiguring drawer TileLBC28, RunNumber 204265, LBN 968 02 Jun 2012 19:51:39 CEST Drawer TileLBC28 reconfigured, RunNumber 204265, LBN 968 02 Jun 2012 19:53:43 CEST Low PPM trigger rate in Tile module LBA06 Tower 1. Tower ID 0x06100401, Eta=0.05 Phi=0.54 (0,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:53:43 CEST Low PPM trigger rate in Tile module LBA06 Tower 7. Tower ID 0x06110501, Eta=0.65 Phi=0.54 (6,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:53:46 CEST Low PPM trigger rate in Tile module LBA06 Tower 3. Tower ID 0x06100501, Eta=0.25 Phi=0.54 (2,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:53:46 CEST Low PPM trigger rate in Tile module LBA06 Tower 9. Tower ID 0x06120401, Eta=0.85 Phi=0.54 (8,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:53:46 CEST Low PPM trigger rate in Tile module LBA06 Tower 2. Tower ID 0x06100403, Eta=0.15 Phi=0.54 (1,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 19:56:52 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:02:42 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:29 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:07:53 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:08:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:13:47 CEST Low PPM trigger rate in Tile module LBA06 Tower 1. Tower ID 0x06100401, Eta=0.05 Phi=0.54 (0,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:13:47 CEST Low PPM trigger rate in Tile module LBA06 Tower 3. Tower ID 0x06100501, Eta=0.25 Phi=0.54 (2,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:13:47 CEST Low PPM trigger rate in Tile module LBA06 Tower 9. Tower ID 0x06120401, Eta=0.85 Phi=0.54 (8,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:13:47 CEST Low PPM trigger rate in Tile module LBA06 Tower 2. Tower ID 0x06100403, Eta=0.15 Phi=0.54 (1,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:13:51 CEST Low PPM trigger rate in Tile module LBA06 Tower 7. Tower ID 0x06110501, Eta=0.65 Phi=0.54 (6,5). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:16:56 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:21:47 CEST Start reconfiguring drawer TileLBA06, RunNumber 204265, LBN 1001 02 Jun 2012 20:21:59 CEST Drawer TileLBA06 reconfigured, RunNumber 204265, LBN 1001 02 Jun 2012 20:22:44 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:26:46 CEST Start reconfiguring drawer TileEBA23, RunNumber 204265, LBN 1005 02 Jun 2012 20:26:58 CEST Drawer TileEBA23 reconfigured, RunNumber 204265, LBN 1005 02 Jun 2012 20:27:14 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:14 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:14 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:17 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:17 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:17 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:31 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:27:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:28:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:32:29 CEST Start reconfiguring drawer TileEBA23, RunNumber 204265, LBN 1011 02 Jun 2012 20:32:41 CEST Drawer TileEBA23 reconfigured, RunNumber 204265, LBN 1011 02 Jun 2012 20:35:09 CEST EBC06 seems to be off (at least the ROD link is off). [Run #204265 LB #1014] 02 Jun 2012 20:36:36 CEST Start reconfiguring drawer TileEBC06, RunNumber 204265, LBN 1015 02 Jun 2012 20:36:48 CEST Drawer TileEBC06 reconfigured, RunNumber 204265, LBN 1015 02 Jun 2012 20:36:58 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:42:45 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:47:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:48:53 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 20:56:59 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:02:47 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:03:31 CEST LBA50 seems to be off (at least the ROD link is off). [Run #204265 LB #1044] 02 Jun 2012 21:04:41 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 1045 02 Jun 2012 21:04:53 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 1045 02 Jun 2012 21:05:08 CEST Start reconfiguring drawer TileLBA50, RunNumber 204265, LBN 1045 02 Jun 2012 21:05:20 CEST Drawer TileLBA50 reconfigured, RunNumber 204265, LBN 1045 02 Jun 2012 21:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:23 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:23 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:23 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:33 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:07:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:08:31 CEST LBC32 seems to be off (at least the ROD link is off). [Run #204265 LB #1049] 02 Jun 2012 21:08:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:10:18 CEST Start reconfiguring drawer TileLBC32, RunNumber 204265, LBN 1050 02 Jun 2012 21:10:31 CEST Drawer TileLBC32 reconfigured, RunNumber 204265, LBN 1050 02 Jun 2012 21:12:21 CEST LBC32 seems to be off (at least the ROD link is off). [Run #204265 LB #1052] 02 Jun 2012 21:15:33 CEST Start reconfiguring drawer TileLBC32, RunNumber 204265, LBN 1055 02 Jun 2012 21:15:45 CEST Drawer TileLBC32 reconfigured, RunNumber 204265, LBN 1055 02 Jun 2012 21:15:49 CEST Low PPM trigger rate in Tile module LBC32 Tower 4. Tower ID 0x07170f01, Eta=-0.35 Phi=3.09 (-4,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:49 CEST Low PPM trigger rate in Tile module LBC32 Tower 9. Tower ID 0x07150e03, Eta=-0.85 Phi=3.09 (-9,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 8. Tower ID 0x07160f01, Eta=-0.75 Phi=3.09 (-8,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 1. Tower ID 0x07170e03, Eta=-0.05 Phi=3.09 (-1,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 2. Tower ID 0x07170e01, Eta=-0.15 Phi=3.09 (-2,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 3. Tower ID 0x07170f03, Eta=-0.25 Phi=3.09 (-3,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 7. Tower ID 0x07160f03, Eta=-0.65 Phi=3.09 (-7,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:15:53 CEST Low PPM trigger rate in Tile module LBC32 Tower 6. Tower ID 0x07160e01, Eta=-0.55 Phi=3.09 (-6,31). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:17:00 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:17:11 CEST LBC54 seems to be off (at least the ROD link is off). [Run #204265 LB #1057] 02 Jun 2012 21:18:38 CEST Start reconfiguring drawer TileLBC54, RunNumber 204265, LBN 1058 02 Jun 2012 21:18:51 CEST Drawer TileLBC54 reconfigured, RunNumber 204265, LBN 1058 02 Jun 2012 21:22:48 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:18 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:18 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:18 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:25 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:25 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:25 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:35 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:27:40 CEST LBC12 seems to be off (at least the ROD link is off). [Run #204265 LB #1067] 02 Jun 2012 21:27:59 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:28:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:29:18 CEST Start reconfiguring drawer TileLBC12, RunNumber 204265, LBN 1069 02 Jun 2012 21:29:30 CEST Drawer TileLBC12 reconfigured, RunNumber 204265, LBN 1069 02 Jun 2012 21:37:02 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:42:49 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:42:51 CEST LBA54 seems to be off (at least the ROD link is off). [Run #204265 LB #1082] 02 Jun 2012 21:44:38 CEST Start reconfiguring drawer TileLBA54, RunNumber 204265, LBN 1084 02 Jun 2012 21:44:51 CEST Drawer TileLBA54 reconfigured, RunNumber 204265, LBN 1084 02 Jun 2012 21:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:26 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:26 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:26 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:47:36 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:48:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:48:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 21:49:21 CEST LBC50 seems to be off (at least the ROD link is off). [Run #204265 LB #1089] 02 Jun 2012 21:50:58 CEST Start reconfiguring drawer TileLBC50, RunNumber 204265, LBN 1090 02 Jun 2012 21:51:11 CEST Drawer TileLBC50 reconfigured, RunNumber 204265, LBN 1090 02 Jun 2012 21:57:03 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:02:51 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:21 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:21 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:21 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:07:31 CEST LBC34 seems to be off (at least the ROD link is off). [Run #204265 LB #1107] 02 Jun 2012 22:07:38 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:08:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:08:58 CEST Start reconfiguring drawer TileLBC34, RunNumber 204265, LBN 1108 02 Jun 2012 22:08:59 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:09:11 CEST Drawer TileLBC34 reconfigured, RunNumber 204265, LBN 1108 02 Jun 2012 22:15:21 CEST LBC02 seems to be off (at least the ROD link is off). [Run #204265 LB #1114] 02 Jun 2012 22:16:48 CEST Start reconfiguring drawer TileLBC02, RunNumber 204265, LBN 1116 02 Jun 2012 22:17:00 CEST Drawer TileLBC02 reconfigured, RunNumber 204265, LBN 1116 02 Jun 2012 22:17:05 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:22:52 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:24:42 CEST LBA59 seems to be off (at least the ROD link is off). [Run #204265 LB #1123] 02 Jun 2012 22:26:09 CEST Start reconfiguring drawer TileLBA59, RunNumber 204265, LBN 1125 02 Jun 2012 22:26:21 CEST Drawer TileLBA59 reconfigured, RunNumber 204265, LBN 1125 02 Jun 2012 22:27:22 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:22 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:22 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:29 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:29 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:29 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:27:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:28:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:29:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:29:13 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:36:11 CEST LBA61 seems to be off (at least the ROD link is off). [Run #204265 LB #1135] 02 Jun 2012 22:37:09 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:37:48 CEST Start reconfiguring drawer TileLBA61, RunNumber 204265, LBN 1136 02 Jun 2012 22:38:00 CEST Drawer TileLBA61 reconfigured, RunNumber 204265, LBN 1136 02 Jun 2012 22:42:53 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:24 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:24 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:24 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:47:40 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:48:04 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:49:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 22:57:11 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:02:55 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:05:42 CEST LBC21 seems to be off (at least the ROD link is off). [Run #204265 LB #1166] 02 Jun 2012 23:07:19 CEST Start reconfiguring drawer TileLBC21, RunNumber 204265, LBN 1167 02 Jun 2012 23:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:31 CEST Drawer TileLBC21 reconfigured, RunNumber 204265, LBN 1167 02 Jun 2012 23:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:07:42 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:08:05 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:09:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:13:42 CEST LBA22 seems to be off (at least the ROD link is off). [Run #204265 LB #1173] 02 Jun 2012 23:15:19 CEST Start reconfiguring drawer TileLBA22, RunNumber 204265, LBN 1175 02 Jun 2012 23:15:31 CEST Drawer TileLBA22 reconfigured, RunNumber 204265, LBN 1175 02 Jun 2012 23:17:12 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:22:56 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:33 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:33 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:33 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:27:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:28:07 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:29:04 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:37:02 CEST LBA33 seems to be off (at least the ROD link is off). [Run #204265 LB #1197] 02 Jun 2012 23:37:14 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:38:49 CEST Start reconfiguring drawer TileLBA33, RunNumber 204265, LBN 1199 02 Jun 2012 23:39:01 CEST Drawer TileLBA33 reconfigured, RunNumber 204265, LBN 1199 02 Jun 2012 23:40:52 CEST LBC51 seems to be off (at least the ROD link is off). [Run #204265 LB #1201] 02 Jun 2012 23:42:29 CEST Start reconfiguring drawer TileLBC51, RunNumber 204265, LBN 1202 02 Jun 2012 23:42:42 CEST Drawer TileLBC51 reconfigured, RunNumber 204265, LBN 1202 02 Jun 2012 23:42:58 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:31 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:31 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:31 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:35 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:35 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:35 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:47:45 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:48:08 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:49:06 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 02 Jun 2012 23:57:15 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:01:52 CEST LBC22 seems to be off (at least the ROD link is off). [Run #204265 LB #1222] 03 Jun 2012 00:02:59 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:03:29 CEST Start reconfiguring drawer TileLBC22, RunNumber 204265, LBN 1224 03 Jun 2012 00:03:42 CEST Drawer TileLBC22 reconfigured, RunNumber 204265, LBN 1224 03 Jun 2012 00:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:32 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:07:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:08:09 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:09:10 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:17:16 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:23:01 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:34 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:34 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:34 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:27:47 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:28:11 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:28:42 CEST EBA63 seems to be off (at least the ROD link is off). [Run #204265 LB #1251] 03 Jun 2012 00:29:12 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:29:22 CEST EBC47 seems to be off (at least the ROD link is off). [Run #204265 LB #1252] 03 Jun 2012 00:30:19 CEST Start reconfiguring drawer TileEBA63, RunNumber 204265, LBN 1253 03 Jun 2012 00:30:31 CEST Drawer TileEBA63 reconfigured, RunNumber 204265, LBN 1253 03 Jun 2012 00:30:49 CEST Start reconfiguring drawer TileEBC47, RunNumber 204265, LBN 1253 03 Jun 2012 00:31:01 CEST Drawer TileEBC47 reconfigured, RunNumber 204265, LBN 1253 03 Jun 2012 00:37:18 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:43:02 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:36 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:36 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:36 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:47:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:48:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:49:14 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 00:57:20 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:03:04 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:37 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:37 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:37 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:07:51 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:08:14 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:09:15 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:15:43 CEST LBC53 seems to be off (at least the ROD link is off). [Run #204265 LB #1298] 03 Jun 2012 01:17:21 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:17:30 CEST Start reconfiguring drawer TileLBC53, RunNumber 204265, LBN 1300 03 Jun 2012 01:17:43 CEST Drawer TileLBC53 reconfigured, RunNumber 204265, LBN 1300 03 Jun 2012 01:23:05 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:27:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:28:16 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:29:17 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:37:23 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:43:07 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:47 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:47 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:47 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:48:18 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:48:23 CEST EBA24 seems to be off (at least the ROD link is off). [Run #204265 LB #1331] 03 Jun 2012 01:49:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:50:10 CEST Start reconfiguring drawer TileEBA24, RunNumber 204265, LBN 1332 03 Jun 2012 01:50:22 CEST Drawer TileEBA24 reconfigured, RunNumber 204265, LBN 1332 03 Jun 2012 01:52:07 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 01:57:24 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:03:09 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:42 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:42 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:42 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:07:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:08:19 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:09:23 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:17:26 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:20:18 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:23:10 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:28:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:28:20 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:29:25 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:32:05 CEST LBA56 seems to be off (at least the ROD link is off). [Run #204265 LB #1377] 03 Jun 2012 02:33:31 CEST Start reconfiguring drawer TileLBA56, RunNumber 204265, LBN 1378 03 Jun 2012 02:33:44 CEST Drawer TileLBA56 reconfigured, RunNumber 204265, LBN 1378 03 Jun 2012 02:37:27 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:38:14 CEST LBA40 seems to be off (at least the ROD link is off). [Run #204265 LB #1383] 03 Jun 2012 02:40:01 CEST Start reconfiguring drawer TileLBA40, RunNumber 204265, LBN 1385 03 Jun 2012 02:40:13 CEST Drawer TileLBA40 reconfigured, RunNumber 204265, LBN 1385 03 Jun 2012 02:43:11 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:51 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:51 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:47:51 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:48:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:48:21 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:49:29 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 02:57:31 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:03:12 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:06:58 CEST Low PPM trigger rate in Tile module EBC01 Tower 4. Tower ID 0x07100102, Eta=-1.25 Phi=0.05 (-13,0). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:45 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:45 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:45 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:07:52 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:08:02 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:08:23 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:09:33 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:11:24 CEST LBC53 seems to be off (at least the ROD link is off). [Run #204265 LB #1417] 03 Jun 2012 03:11:44 CEST LBA61 seems to be off (at least the ROD link is off). [Run #204265 LB #1418] 03 Jun 2012 03:12:51 CEST Start reconfiguring drawer TileLBC53, RunNumber 204265, LBN 1419 03 Jun 2012 03:13:04 CEST Drawer TileLBC53 reconfigured, RunNumber 204265, LBN 1419 03 Jun 2012 03:13:21 CEST Start reconfiguring drawer TileLBA61, RunNumber 204265, LBN 1419 03 Jun 2012 03:13:33 CEST Drawer TileLBA61 reconfigured, RunNumber 204265, LBN 1419 03 Jun 2012 03:17:32 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:23:13 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:46 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:53 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:53 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:27:53 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:28:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:28:24 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:29:34 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:32:55 CEST LBA52 seems to be off (at least the ROD link is off). [Run #204265 LB #1439] 03 Jun 2012 03:33:15 CEST LBA51 seems to be off (at least the ROD link is off). [Run #204265 LB #1439] 03 Jun 2012 03:34:32 CEST Start reconfiguring drawer TileLBA52, RunNumber 204265, LBN 1440 03 Jun 2012 03:34:44 CEST Drawer TileLBA52 reconfigured, RunNumber 204265, LBN 1440 03 Jun 2012 03:34:53 CEST Start reconfiguring drawer TileLBA51, RunNumber 204265, LBN 1440 03 Jun 2012 03:35:05 CEST Drawer TileLBA51 reconfigured, RunNumber 204265, LBN 1440 03 Jun 2012 03:37:34 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:43:14 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:48 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:48 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:48 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:48:05 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:48:28 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:49:36 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:56:44 CEST LBC14 seems to be off (at least the ROD link is off). [Run #204265 LB #1462] 03 Jun 2012 03:57:35 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 03:58:11 CEST Start reconfiguring drawer TileLBC14, RunNumber 204265, LBN 1463 03 Jun 2012 03:58:24 CEST Drawer TileLBC14 reconfigured, RunNumber 204265, LBN 1463 03 Jun 2012 04:03:16 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:49 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:07:56 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:08:06 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:08:30 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:09:37 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:17:36 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:23:17 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:15 CEST LBA46 seems to be off (at least the ROD link is off). [Run #204265 LB #1492] 03 Jun 2012 04:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:50 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:28:07 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:28:34 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:29:02 CEST Start reconfiguring drawer TileLBA46, RunNumber 204265, LBN 1494 03 Jun 2012 04:29:04 CEST LBC10 seems to be off (at least the ROD link is off). [Run #204265 LB #1494] 03 Jun 2012 04:29:14 CEST Drawer TileLBA46 reconfigured, RunNumber 204265, LBN 1494 03 Jun 2012 04:29:38 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:30:52 CEST Start reconfiguring drawer TileLBC10, RunNumber 204265, LBN 1496 03 Jun 2012 04:31:04 CEST Drawer TileLBC10 reconfigured, RunNumber 204265, LBN 1496 03 Jun 2012 04:37:37 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:43:21 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:47:54 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:48:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:48:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:48:01 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:48:11 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:48:38 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:49:42 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 04:57:41 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:03:22 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:07:55 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:07:55 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:07:55 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:08:02 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:08:02 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:08:02 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:08:12 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:08:39 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:09:43 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:17:42 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:23:23 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:27:57 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:28:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:28:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:28:03 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:28:13 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:28:40 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:29:06 CEST EBA53 seems to be off (at least the ROD link is off). [Run #204265 LB #1555] 03 Jun 2012 05:29:44 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:30:43 CEST Start reconfiguring drawer TileEBA53, RunNumber 204265, LBN 1556 03 Jun 2012 05:30:55 CEST Drawer TileEBA53 reconfigured, RunNumber 204265, LBN 1556 03 Jun 2012 05:37:43 CEST Low PPM trigger rate in Tile module LBA59 Tower 3. Tower ID 0x061c0a00, Eta=0.25 Phi=-0.54 (2,58). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:43:27 CEST Low PPM trigger rate in Tile module EBA23 Tower 3. Tower ID 0x06160602, Eta=1.15 Phi=2.21 (11,22). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 7. Tower ID 0x07120f03, Eta=-0.65 Phi=1.52 (-7,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 5. Tower ID 0x07120e03, Eta=-0.45 Phi=1.52 (-5,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:00 CEST Low PPM trigger rate in Tile module LBC16 Tower 2. Tower ID 0x07130e01, Eta=-0.15 Phi=1.52 (-2,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:07 CEST Low PPM trigger rate in Tile module LBC16 Tower 3. Tower ID 0x07130f03, Eta=-0.25 Phi=1.52 (-3,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:07 CEST Low PPM trigger rate in Tile module LBC16 Tower 6. Tower ID 0x07120e01, Eta=-0.55 Phi=1.52 (-6,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:07 CEST Low PPM trigger rate in Tile module LBC16 Tower 1. Tower ID 0x07130e03, Eta=-0.05 Phi=1.52 (-1,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:17 CEST Low PPM trigger rate in Tile module LBC16 Tower 9. Tower ID 0x07110e03, Eta=-0.85 Phi=1.52 (-9,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:48:41 CEST Low PPM trigger rate in Tile module LBC16 Tower 4. Tower ID 0x07130f01, Eta=-0.35 Phi=1.52 (-4,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:49:45 CEST Low PPM trigger rate in Tile module LBC16 Tower 8. Tower ID 0x07120f01, Eta=-0.75 Phi=1.52 (-8,15). Check L1Calo map; module reconfiguration might be needed. 03 Jun 2012 05:53:51 CEST Low PPM trigger rate in Tile module EBC01 Tower 1. Tower ID 0x07110100, Eta=-0.95 Phi=0.05 (-10,0). Check L1Calo map; module reconfiguration might be needed.