# module, start date, end date, comment
# Description. One can specify:
# "ALL" - all modules
# "LBC" or "LBA" - entire partition (LBC,LBA)
# "EBA" or "EBC" - entire partition (EBC,EBA)
# "EB*" - all extended barrel
# "LB*" - all long barrel
# "LBC11" - a single module
# XXXXXX - (X- is a number) particular status (like 202221 recovery mode)
# XX+XX - type of trips to ignore
#
# S.Chekanov (ANL)
# ALL,2014-01-24 06:59:00,2014-01-24 21:01:00,all are ignored during day
# EBC42,2014-01-26 21:00:00,2014-01-27 07:00:00, ignored using 8-9pm test
EBC49,2015-11-17 05:00:00,2015-11-17 12:00:00, https://atlasop.cern.ch/elisa/display/285944
ALL,2015-11-13 01:00:00,2015-11-13 23:00:00, all are OFF
ALL,2015-12-14 01:00:00,2016-02-05 23:00:00, all are OFF
EBC31,2015-11-11 22:00:00,2015-11-12 02:00:00, https://atlasop.cern.ch/elisa/display/285402
EBC29,2015-11-11 22:00:00,2015-11-12 02:00:00, https://atlasop.cern.ch/elisa/display/285402
ALL,2015-11-09 15:00:00,2015-11-09 20:00:09, Manual interventon
EBA52,2015-10-31 00:00:00,2015-11-01 05:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/283814
EBA55,2015-11-02 19:00:00,2015-11-03 05:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/284304
LBC45,2015-10-29 10:00:09,2015-10-29 15:00:09, Manual restart https://atlasop.cern.ch/elisa/display/283489
LBC38,2015-10-29 10:00:09,2015-10-29 15:00:09, Manual restart https://atlasop.cern.ch/elisa/display/283489
EBC11,2015-10-28 00:00:09,2015-10-28 15:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/283257
EBC20,2015-10-30 00:00:09,2015-11-01 3:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/283870
LBC28,2015-10-12 00:00:09,2015-10-12 3:00:09, lost of communication with HV-Micro inside drawer
LBA38,2015-10-08 07:00:09,2015-10-08 12:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/280739
LBA04,2015-10-11 09:00:09,2015-10-11 12:00:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/280416
EBA19, 2015-10-06 21:00:09,2015-10-07 01:55:09, Automatic Power Cycle https://atlasop.cern.ch/elisa/display/280033
LBC08, 2015-09-30 06:00:09,2015-09-30 08:54:09, automatic power cycle https://atlasop.cern.ch/elisa/display/280033
EBA38, 2015-10-01 11:00:09,2015-10-01 18:54:09, data corruption https://atlasop.cern.ch/elisa/display/278942
LBA28,2015-09-17 07:00:09,2015-09-17 15:54:09,power cycle
LBC09,2015-09-26 07:00:09,2015-09-26 11:54:09,power cycle https://atlasop.cern.ch/elisa/display/278247
LBC54,2015-09-21 07:00:09,2015-09-21 15:54:09,power cycle https://atlasop.cern.ch/elisa/display/277303
EBC,2015-08-01 15:19:26,2015-08-01 21:19:26,power cycle https://atlasop.cern.ch/elisa/display/270971
LBC14,2015-08-05 18:54:09,2015-08-05 22:54:09,power cycle https://atlasop.cern.ch/elisa/display/271415
EBA58,2015-08-21 11:30:19,2015-08-21 20:30:19,power cycle https://atlasop.cern.ch/elisa/display/273479
EBC21,2015-07-01 10:00:00,2015-12-30 14:00:00, EBC21 is in the emergency mode
EBC10,2015-07-12 23:00:00,2015-12-08 14:00:00, EBC10 is in the emergency mode
LBC,2015-07-13 09:00:00, 2015-07-13 11:00:00, reconfigured https://atlasop.cern.ch/elisa/display/268711
EBA,2015-07-10 12:00:00, 2015-07-10 18:00:00, reconfigured https://atlasop.cern.ch/elisa/display/268374
EBC,2015-07-09 16:00:00, 2015-07-09 20:00:00, reconfigured https://atlasop.cern.ch/elisa/display/268243
LBC55,2015-06-30 14:00:00,2015-06-30 21:00:00, discarding 75.5396% of events and power cicled then
LBC62,2015-06-22 10:00:00,2015-06-22 14:00:00, manual intervention
EBC62,2015-06-18 14:00:00,2015-06-22 18:00:00, work on L1Calo https://atlasop.cern.ch/elisa/display/265601
ALL,2015-06-15 20:00:00,2015-06-16 23:00:00, Bulk power supply problem
LBA,2015-06-13 14:00:00,2015-06-13 21:00:00, 200V power supply problem
LBA43,2015-05-12 14:00:00,2015-05-12 18:00:00, Intervention was necessary to reboot the server which handles the ELMB monitoring the detector was all the time ON (Filipe e-mail)
LBC20,2015-05-11 00:00:00,2015-05-11 22:00:00, HV related https://atlasop.cern.ch/elisa/display/260676
LBA56,2015-05-11 00:00:00,2015-05-15 17:00:00, off due to temprature problem http://atlasop.cern.ch/elisa/display/260251
EBA02,2015-04-16 14:00:00,2015-04-16 17:00:00, power-cycled to fix discarding events https://atlasop.cern.ch/elisa/display/257996
EBA08,2015-04-17 20:00:00,2015-04-17 23:00:00,HV_830 tripped restarted HV side https://atlasop.cern.ch/elisa/display/258168
ALL,2015-04-28 12:00:00,2015-04-28 15:00:00, Power-cycled to verify deskew adjustment
ALL,2015-04-20 12:00:00,2015-04-20 20:00:00, power is off
EBC21,2015-04-18 13:00:00,2015-07-25 18:00:00, Dead module since April 18
LBA35,2015-04-25 12:00:00,2015-04-25 15:00:00, power cycling https://atlasop.cern.ch/elisa/display/258989
EBC62, 2015-04-22 10:00:00,2015-04-22 13:00:00, power-cycled to fix timing jump
EBA57,2015-04-25 13:00:00,2015-04-25 22:00:00, power cycling https://atlasop.cern.ch/elisa/display/258990
EBC33,2015-04-14 17:00:00,2015-04-14 20:00:00, power cycling https://atlasop.cern.ch/elisa/display/257754
LBC20,2015-04-15 10:00:00,2015-04-15 15:00:00, PMT HV https://atlasop.cern.ch/elisa/display/257825
LBA56,2015-04-14 10:00:00,2015-04-14 15:00:00, PMT HV https://atlasop.cern.ch/elisa/display/257746
LBA47,2015-03-26 10:00:00,2015-03-26 15:00:00, https://atlasop.cern.ch/elisa/display/255745
EBC10,2015-03-25 1:00:00,2015-03-25 10:00:00, https://atlasop.cern.ch/elisa/display/255749
ALL,2015-03-23 06:00:00,2015-03-23 21:00:00, HV off
EBC10,2015-03-14 10:00:00,2015-03-19 20:00:00, work on HV
ALL,2015-03-19 10:00:00,2015-03-19 20:00:00, cooling failure
ALL,2015-03-13 10:00:00,2015-03-13 21:00:00, power cycling
EBC37,2015-03-05 15:00:00,2015-03-05 21:00:00, power cycling
LBC20,2015-03-11 12:00:00,2015-03-11 15:00:00, intervention
LBA47,2015-03-06 13:00:00,2015-03-06 15:00:00, manual
LBA56,2015-03-05 01:00:00,2015-03-06 19:00:00, manual
LBC18,2015-03-05 01:00:00,2015-03-05 21:00:00, power cycling
LBC37,2015-03-05 01:00:00,2015-03-05 20:00:00, power cycling
LBC,2015-03-04 01:00:00,2015-03-04 18:00:00, power cycling
ALL,2015-01-01 01:00:00,2015-02-10 20:00:00, off after break
LBA10,2015-01-01 01:00:00,2015-12-10 20:00:00, Dead module since Jan 2015