# LVPS trip messages from MRS DAQ LogManager. S.Chekanov (ANL) 15 May 2018 01:57:23 CEST LBA30 seems to be off (at least the ROD link is off), maybe it tripped before the start of run. 15 May 2018 01:57:23 CEST LBA29 seems to be off (at least the ROD link is off), maybe it tripped before the start of run. 15 May 2018 01:57:23 CEST LBA31 seems to be off (at least the ROD link is off), maybe it tripped before the start of run. 15 May 2018 02:01:14 CEST Start reconfiguring drawer TileLBA30, RunNumber 350220, LBN 82 15 May 2018 02:01:40 CEST Drawer TileLBA30 reconfigured, RunNumber 350220, LBN 83 15 May 2018 02:01:49 CEST Start reconfiguring drawer TileLBA29, RunNumber 350220, LBN 83 15 May 2018 02:01:52 CEST Drawer LBA29 is currently disabled. Power cycling is not possible now. 15 May 2018 02:02:14 CEST Drawer TileLBA29 reconfigured, RunNumber 350220, LBN 83 15 May 2018 02:02:23 CEST Start reconfiguring drawer TileLBA31, RunNumber 350220, LBN 83 15 May 2018 02:02:44 CEST LBA31 is discarding 100% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:02:49 CEST Drawer TileLBA31 reconfigured, RunNumber 350220, LBN 84 15 May 2018 02:02:57 CEST Start reconfiguring drawer TileLBA31, RunNumber 350220, LBN 84 15 May 2018 02:03:23 CEST Drawer TileLBA31 reconfigured, RunNumber 350220, LBN 84 15 May 2018 02:03:34 CEST Start reconfiguring drawer TileLBA32, RunNumber 350220, LBN 85 15 May 2018 02:03:51 CEST Drawer LBA32 is currently disabled. Power cycling is not possible now. 15 May 2018 02:04:00 CEST Drawer TileLBA32 reconfigured, RunNumber 350220, LBN 86 15 May 2018 02:04:08 CEST Start reconfiguring drawer TileLBA33, RunNumber 350220, LBN 86 15 May 2018 02:04:34 CEST Drawer TileLBA33 reconfigured, RunNumber 350220, LBN 87 15 May 2018 02:04:42 CEST Start reconfiguring drawer TileLBA35, RunNumber 350220, LBN 87 15 May 2018 02:04:48 CEST LBA32 is discarding 99.9996% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:04:52 CEST Drawer LBA35 is currently disabled. Power cycling is not possible now. 15 May 2018 02:04:59 CEST LBA34 is discarding 99.9995% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:04:59 CEST LBA35 is discarding 100% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:05:08 CEST Drawer TileLBA35 reconfigured, RunNumber 350220, LBN 87 15 May 2018 02:05:17 CEST Start reconfiguring drawer TileLBA34, RunNumber 350220, LBN 88 15 May 2018 02:05:43 CEST Drawer TileLBA34 reconfigured, RunNumber 350220, LBN 88 15 May 2018 02:05:51 CEST Start reconfiguring drawer TileLBA29, RunNumber 350220, LBN 88 15 May 2018 02:05:52 CEST Drawer LBA29 is currently disabled. Power cycling is not possible now. 15 May 2018 02:06:03 CEST LBA29 is discarding 100% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:06:04 CEST LBA30 is discarding 100% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:06:17 CEST Drawer TileLBA29 reconfigured, RunNumber 350220, LBN 89 15 May 2018 02:06:25 CEST Start reconfiguring drawer TileLBA30, RunNumber 350220, LBN 89 15 May 2018 02:06:51 CEST Drawer TileLBA30 reconfigured, RunNumber 350220, LBN 89 15 May 2018 02:06:51 CEST Drawer LBA30 is currently disabled. Power cycling is not possible now. 15 May 2018 02:07:00 CEST Start reconfiguring drawer TileLBA32, RunNumber 350220, LBN 89 15 May 2018 02:07:08 CEST LBA31 is discarding 100% of events. It will be automatically reconfigured now. Please check the next MRS messages. 15 May 2018 02:07:26 CEST Drawer TileLBA32 reconfigured, RunNumber 350220, LBN 90 15 May 2018 02:07:34 CEST Start reconfiguring drawer TileLBA35, RunNumber 350220, LBN 90 15 May 2018 02:08:00 CEST Drawer TileLBA35 reconfigured, RunNumber 350220, LBN 90 15 May 2018 02:08:08 CEST Start reconfiguring drawer TileLBA34, RunNumber 350220, LBN 90 15 May 2018 02:08:34 CEST Drawer TileLBA34 reconfigured, RunNumber 350220, LBN 91 15 May 2018 02:08:43 CEST Start reconfiguring drawer TileLBA31, RunNumber 350220, LBN 91 15 May 2018 02:08:51 CEST Drawer LBA31 is currently disabled. Power cycling is not possible now. 15 May 2018 02:09:08 CEST Drawer TileLBA31 reconfigured, RunNumber 350220, LBN 91 15 May 2018 02:09:17 CEST Start reconfiguring drawer TileLBA29, RunNumber 350220, LBN 92 15 May 2018 02:09:43 CEST Drawer TileLBA29 reconfigured, RunNumber 350220, LBN 92 15 May 2018 02:09:51 CEST Start reconfiguring drawer TileLBA30, RunNumber 350220, LBN 92 15 May 2018 02:10:17 CEST Drawer TileLBA30 reconfigured, RunNumber 350220, LBN 93 15 May 2018 02:10:26 CEST Start reconfiguring drawer TileLBA31, RunNumber 350220, LBN 93 15 May 2018 02:10:51 CEST Drawer TileLBA31 reconfigured, RunNumber 350220, LBN 93