# LVPS trip messages from MRS DAQ LogManager. S.Chekanov (ANL) 02 Sep 2018 13:42:49 CEST Start reconfiguring drawer TileEBA10, RunNumber 359717, LBN 91 02 Sep 2018 13:42:53 CEST Drawer EBA10 is currently disabled. Power cycling is not possible now. 02 Sep 2018 13:43:13 CEST Drawer TileEBA10 reconfigured, RunNumber 359717, LBN 91 02 Sep 2018 17:28:44 CEST Start reconfiguring drawer TileEBC60, RunNumber 359717, LBN 333 02 Sep 2018 17:28:52 CEST Drawer EBC60 is currently disabled. Power cycling is not possible now. 02 Sep 2018 17:29:08 CEST Drawer TileEBC60 reconfigured, RunNumber 359717, LBN 333 02 Sep 2018 18:15:55 CEST EBC41 seems to be off (at least the ROD link is off). [Run #359717 LB #385] 02 Sep 2018 18:17:05 CEST Start reconfiguring drawer TileEBC41, RunNumber 359717, LBN 386 02 Sep 2018 18:17:30 CEST Drawer TileEBC41 reconfigured, RunNumber 359717, LBN 387 02 Sep 2018 18:18:14 CEST EBC41 is discarding 32.5413% of events. It will be automatically reconfigured now. Please check the next MRS messages. 02 Sep 2018 18:18:20 CEST Start reconfiguring drawer TileEBC41, RunNumber 359717, LBN 388 02 Sep 2018 18:18:35 CEST EBC41 seems to be off (at least the ROD link is off). [Run #359717 LB #388] 02 Sep 2018 18:18:45 CEST Drawer TileEBC41 reconfigured, RunNumber 359717, LBN 388 02 Sep 2018 18:36:52 CEST Drawer EBC41 is currently disabled. Power cycling is not possible now. 02 Sep 2018 18:36:54 CEST Start reconfiguring drawer TileEBC41, RunNumber 359717, LBN 408 02 Sep 2018 18:37:18 CEST Drawer TileEBC41 reconfigured, RunNumber 359717, LBN 408