# LVPS trip messages from MRS DAQ LogManager. S.Chekanov (ANL) 16 Oct 2018 00:09:59 CEST EBA51 seems to be off (at least the ROD link is off), maybe it tripped before the start of run. 16 Oct 2018 00:57:44 CEST Start reconfiguring drawer TileEBA51, RunNumber 363664, LBN 48 16 Oct 2018 00:57:51 CEST Drawer EBA51 is currently disabled. Power cycling is not possible now. 16 Oct 2018 00:58:08 CEST Drawer TileEBA51 reconfigured, RunNumber 363664, LBN 49 16 Oct 2018 00:58:52 CEST EBA51 is discarding 49.1758% of events. It will be automatically reconfigured now. Please check the next MRS messages. 16 Oct 2018 00:58:59 CEST Start reconfiguring drawer TileEBA51, RunNumber 363664, LBN 49 16 Oct 2018 00:59:23 CEST Drawer TileEBA51 reconfigured, RunNumber 363664, LBN 50 16 Oct 2018 01:02:06 CEST Start reconfiguring drawer TileEBA51, RunNumber 363664, LBN 53 16 Oct 2018 01:02:31 CEST Drawer TileEBA51 reconfigured, RunNumber 363664, LBN 53 16 Oct 2018 01:03:15 CEST EBA51 is discarding 99.2553% of events. It will be automatically reconfigured now. Please check the next MRS messages. 16 Oct 2018 01:03:21 CEST Start reconfiguring drawer TileEBA51, RunNumber 363664, LBN 54 16 Oct 2018 01:03:46 CEST Drawer TileEBA51 reconfigured, RunNumber 363664, LBN 54