itk:testbeam
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
itk:testbeam [2016/09/30 17:29] – asc | itk:testbeam [2016/10/04 15:11] (current) – asc | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== | ====== | ||
- | (prepared | + | (some notes by S.Chekanov) |
Line 21: | Line 21: | ||
Details on 2 tests: | Details on 2 tests: | ||
- | 1) Testing RTI (USA vendor) to test bum bonding. | + | 1) Testing RTI (USA vendor) to test bump bonding. |
Line 30: | Line 30: | ||
Here is the setup at the end-station A: | Here is the setup at the end-station A: | ||
+ | |||
+ | This is the RTI module (uncovered): | ||
{{: | {{: | ||
+ | |||
+ | This is the RTI module + RD53 prototype (uncovered): | ||
{{: | {{: | ||
Telescope: | Telescope: | ||
+ | |||
{{: | {{: | ||
Control room upstairs: | Control room upstairs: | ||
+ | |||
{{: | {{: | ||
Line 189: | Line 195: | ||
- | Both modules from RTI have shown signs of degradation performance. After about ~6-8h, we start to see problems for the analog | + | Both modules from RTI have shown signs of degradation |
- | channels. The occupancy for uncalibrated module goes from 99% to 70% after 6h. The noise increases by a factor 2. | + | |
+ | This problem is not related to the active beam, since the red module was not under the beam on Sep 28. | ||
- | This problem is not related to the active beam, since the red module was not under the beam in Sep 28. | ||
itk/testbeam.1475256599.txt.gz · Last modified: 2016/09/30 17:29 by asc