User Tools

Site Tools


itk:testbeam_febmi2017

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
itk:testbeam_febmi2017 [2017/03/26 19:00]
dfrizzell [Current Status]
itk:testbeam_febmi2017 [2017/04/06 15:21] (current)
asc [Location]
Line 4: Line 4:
 The main goal of this testbeam is to test HVCMOS pixel sensors. The University of Geneva  provides the telescope, DAQ  and technical expertise to set it up and use it. The main goal of this testbeam is to test HVCMOS pixel sensors. The University of Geneva  provides the telescope, DAQ  and technical expertise to set it up and use it.
  
 +<fc #FF0000>__**Read the {{:itk:fermilab_testbeam_manual_march2017.pdf| Testbeam Manual}} before and during your shift!**__</fc>
  
 A outline of the sample test schedule is here https://docs.google.com/spreadsheets/d/1Uv5hGlnCU5rnV7FzXFXE4O0cko_fOGiu8kYgUpBxdu8/edit#gid=876192247 A outline of the sample test schedule is here https://docs.google.com/spreadsheets/d/1Uv5hGlnCU5rnV7FzXFXE4O0cko_fOGiu8kYgUpBxdu8/edit#gid=876192247
  
-work in progress for operating the telescope can be found here:+living document for operating the telescope can be found here:
 https://docs.google.com/document/d/1c0UE1NvmkBhJ4uaZUzRNWKqHAOI5j43DbJwnIyXC7yM/edit https://docs.google.com/document/d/1c0UE1NvmkBhJ4uaZUzRNWKqHAOI5j43DbJwnIyXC7yM/edit
 ====== Current Status ====== ====== Current Status ======
-Updated Last: Mar 26 14:00 +Updated Last: Apr 4  10:00pm 
-Taking data, despite DCS issues. We are forced to power the Car Board from external Power supply+ 
 +Taking data. We have cooling system "working". Would still like to understand the humidity more. Some of the samples have been taking to irradiations.
 ====== Argonne Equipment at FTBF Inventory List ====== ====== Argonne Equipment at FTBF Inventory List ======
  
Line 22: Line 24:
   * Bertan 380N HV power supply in crate   * Bertan 380N HV power supply in crate
   * Chiller Plate + fittings and hose    * Chiller Plate + fittings and hose 
 +  * Single Chip Card with bare FEI4
  
 ====== Available equipment at TestBeam area ====== ====== Available equipment at TestBeam area ======
Line 94: Line 97:
  
 The data is being exported to the eos file system here:  The data is being exported to the eos file system here: 
-**/eos/atlas/atlascerngroupdisk/pixel-upgrade/itk/BeamTest/fermilab_2017_march_fei4tel + 
-**+<code> 
 +/eos/atlas/atlascerngroupdisk/pixel-upgrade/itk/BeamTest/fermilab_2017_march_fei4tel 
 +</code> 
 + 
 +To mount eos, do this: 
 +<code> 
 +mkdir eos; eosmount eos 
 +</code> 
 + 
 +The data can also be found at the ANL cluster: 
 + 
 +<code> 
 +/cnfs/data1/users/chekanov/ITK/itk/BeamTest/fermilab_2017_march_fei4tel 
 +</code> 
 For information on updating the data from fermilab local files see 'Backup on EOS': For information on updating the data from fermilab local files see 'Backup on EOS':
 https://twiki.cern.ch/twiki/bin/viewauth/GeneveAtlas/TB2017_Fermilab https://twiki.cern.ch/twiki/bin/viewauth/GeneveAtlas/TB2017_Fermilab
Line 106: Line 123:
 /afs/cern.ch/user/d/dfrizzel/proteus/ /afs/cern.ch/user/d/dfrizzel/proteus/
  
-Preliminary analysis can be found at :  +Analysis code with Fermilab beam configuration can be found at: 
-**/afs/cern.ch/user/d/dfrizzel/pixelAnalysis/analysis/2017-fnal-h35-frizz**+/afs/cern.ch/user/d/dfrizzel/pixelAnalysis/analysis 
 + 
 +Preliminary results of this code can be found at :  
 +**/afs/cern.ch/work/d/dfrizzel/public/pixelAnalysis/output**
  
 Can also be obtained from gitlab instructions found at : Can also be obtained from gitlab instructions found at :
itk/testbeam_febmi2017.1490554817.txt.gz · Last modified: 2017/03/26 19:00 by dfrizzell